Treatment sector: Intervention on the mitral valve (valve between the left atrium and the left ventricle) using a catheter (insertion of a tube, e.g. through a small incision in the groin) (KCHK-MK-KATH)

Designation Zählleistungsbereich Koronarchirurgische Operationen
Shortcut HCH_MK_KATH
Counts to the treatment area HCH
Number of cases 65
Documentation rate 100 %

Summary result:

In 3 of 3 quality characteristics, the quality objective was achieved.
No assessment is possible for any quality characteristic


Number of patients treated: 65

Quality objective achieved
Quality objective not achieved

The results in detail

Quality criterion
Hospital result
and target area
Quality objective
achieved?
All information
This is how rarely serious complications occurred during the hospital stay due to the procedure
Hospital: 7,69 %
Target area: at most 10,12 %
Quality objective achieved
This is how often the planned result of the intervention was achieved
Hospital: 89,23 %
Target area: at least 83,33 %
Quality objective achieved
This is how rarely patients died in hospital as a result of an urgent planned procedure on the mitral valve with a catheter
Hospital: 0,00 %
as rarely as possible
Evaluation is not available
Ratio of actual to expected number of patients who died in hospital
Hospital: 0,00
Target area: at most 3,24
Quality objective achieved